When time is money, Use Appion
tools for the job
All Products | G5Twin | TEZ8 | TEZ6 | Core Control & Removal Tools | Hoses & Oils | Scales & Gauges | Spare Parts
Please contact us on 1300 277 466 for pricing, cost and availability.
Faceplate Port Cover for the TEZ8 Vacuum Pump
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant. See these Tech Bulletins for more information.
WARNING:
Tampering with or attempting to repair a machine used with A2L refrigerants is prohibited unless performed by an Appion Factory Trained Service personnel.
Compatible Products:
Please contact us on 1300 277 466 for pricing, cost and availability.
This Motor Support Bracket works with the TEZ8 Vacuum Pump.
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant. See these Tech Bulletins for more information.
WARNING:
Tampering with or attempting to repair a machine used with A2L refrigerants is prohibited unless performed by an Appion Factory Trained Service personnel.
Please contact us on 1300 277 466 for pricing, cost and availability.
TEZOM Cartridge Support Bracket for the TEZ8 Vacuum Pump
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant. See these Tech Bulletins for more information.
WARNING:
Tampering with or attempting to repair a machine used with A2L refrigerants is prohibited unless performed by an Appion Factory Trained Service personnel.
Please contact us on 1300 277 466 for pricing, cost and availability.
Debris Tube Door for the TEZ8 Vacuum Pump
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant. See these Tech Bulletins for more information.
Compatible Products:
WARNING:
Tampering with or attempting to repair a machine used with A2L refrigerants is prohibited unless performed by an Appion Factory Trained Service personnel.
Please contact us on 1300 277 466 for pricing, cost and availability.
Tez8 Internal Rebuild Kit
The KTT881-R includes all of the seals, o-rings, valves, and springs to rebuild the TEZ8 Vacuum Pump internals. Bring your old TEZ8 back to life with the KTT881-R!
This Kit Includes
(2) Shaft Seal
(2) End Plate to Cylinder O-ring
(2) First Stage Vane
(2) Second Stage Vane
(1) Valve Chamber to Cylinder O-ring
(4) Valve Spring
(4) Steel Dowel Pin
(1) First Stage Valve
(1) Second Stage Valve
(2) End Plate to Valve Chamber O-ring
(1) End Plate to Oil Pump O-ring
(1) Oil Pump Housing O-ring
(2) Brass Output O-ring
(1) Brass Output to Valve Chamber O-ring
(2) Input Tree Assembly O-ring
(1) Debris Tube O-ring (Black)
(1) Debris Tube O-ring (Red)
(1) 1/4" Flare Cap Seal
(2) 3/8" Flare Cap Seal
(1) 1/2" Flare Cap Seal
(2) Brass Input O-ring
(1) Input O-ring
(1) Barbed Oil Tube Fitting O-ring
Useful Information
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant.
Compatible Products:
TEZ8
Please contact us on 1300 277 466 for pricing, cost and availability.
Debris Tube Door for the TEZ8 Vacuum Pump
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant. See these Tech Bulletins for more information.
Tampering with or attempting to repair a machine used with A2L refrigerants is prohibited unless performed by an Appion Factory Trained Service personnel.
Compatible Products:
Please contact us on 1300 277 466 for pricing, cost and availability.
WARNING:
TEZ8 External Maintence Kit
The KTT840-R includes all of the external sealing components of the TEZ8 Vacuum Pump.
This Kit Includes
(1) 1/4" MegaSeal Cap with Strap
(2) 3/8" MegaSeal Cap with Strap
(1) 1/2" MegaSeal Cap with Strap
(2) Input Tree Assembly O-ring
(1) Debris Tube O-ring (Black)
(1) Debris Tube O-ring (Red)
(1) Debris Catch Tube
(1) TEZOM Seal
(1) TEZOM Secondary Seal
Useful Information
Technical Bulletins
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant.
Compatible Products:
TEZ8
Please contact us on 1300 277 466 for pricing, cost and availability.
Motor Start Capacitor for the TEZ8 Vacuum Pump
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant. See these Tech Bulletins for more information.
Compatible Products:
Please contact us on 1300 277 466 for pricing, cost and availability.
Faceplate with Label for the TEZ8 Vacuum Pump
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant. See these Tech Bulletins for more information.
WARNING:
Tampering with or attempting to repair a machine used with A2L refrigerants is prohibited unless performed by an Appion Factory Trained Service personnel.
Compatible Products:
Please contact us on 1300 277 466 for pricing, cost and availability.
Now featuring a thicker design to make your machine more robust. To account for the new thichness, your Case Side Panel will include (2) new bolts and nuts to assist in replacement.
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant. See these Tech Bulletins for more information.
Compatible Products:
Please contact us on 1300 277 466 for pricing, cost and availability.
Exhaust Chamber Assembly for the TEZ8 Vacuum Pump
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant. See these Tech Bulletins for more information.
Compatible Products:
WARNING:
Tampering with or attempting to repair a machine used with A2L refrigerants is prohibited unless performed by an Appion Factory Trained Service personnel.
Important Notice: Buying from unauthorized online sellers could void your products warranty. This policy shields customers from acquiring pre-owned, damaged, or stolen items. Please be aware that Ebay and Amazon are NOT approved distributors.
Please contact us on 1300 277 466 for pricing, cost and availability.
Oil Port Shipping Cover for the TEZ8 Vacuum Pump
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant. See these Tech Bulletins for more information.
WARNING:
Tampering with or attempting to repair a machine used with A2L refrigerants is prohibited unless performed by an Appion Factory Trained Service personnel.
Compatible Products:
Please contact us on 1300 277 466 for pricing, cost and availability.
Case Side Warning Label (TEZOM Side) for the TEZ8 Vacuum Pump
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant. See these Tech Bulletins for more information.
Compatible Products:
Please contact us on 1300 277 466 for pricing, cost and availability.
Case Side Label for the TEZ8 Vacuum Pump
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant. See these Tech Bulletins for more information.
Compatible Products:
TEZ8
Please contact us on 1300 277 466 for pricing, cost and availability.
Faceplate Label for the TEZ8 Vacuum Pump
Always wear gloves and eye protection and follow proper safety practices when handling refrigerant. See these Tech Bulletins for more information.
Compatible Products:

